HS2 series moulded case circuit breaker is a new designed MCCB developed and manufacture adopting advanced international technology.It has the advantages of compacting structure,small volume,and international high breaking capacity.The inner device is moulding installed,adopt the terminal protective cover to keep safe and the different colors of the basic board and covering board to increase the beauty.
HS2 MCCB is applicable circuit of AC 50Hz/60Hz,rated insulation voltage 660V,rated operating voltage up to 250V(DC).The rated operating current is 12.5A-1600A,for distribute energy of electricity and infrquent making and breaking circuit,and infrequent starting of squirrel cage motor(raged operating current up to 400A) at normal condition with the function of the protection against overload and short circuit and under voltage.
HS2 MCCB complies with standard of IEC 947-2
Trip Characteristic
Rated current of release (A) |
Thermodynamic release(Ambient temp+40) |
Operational current of
magnetic release(A) |
1.05ln(cold state)opertive time (h) |
1.30ln(hot state)opertive time(h) |
12.5 ln 63 |
1 |
<1 |
10-50ln |
63 ln 250 |
2 |
<2 |
10ln 20% |
250<ln 1600 |
2 |
<2 |
5-10ln 20% |
Rated current of
release (A) |
Thermodynamic release(Ambient temp+40) |
Action current
of magnetic
release(A) |
1.0ln(cold state)
non-opertive time(h) |
1.20ln(hot state)
opertive time(h) |
1.50ln(hot state) non-
opertive time(h) |
7.2ln(hot state)
opertive time (h) |
12.5 ln 63 |
2 |
<2 |
2min(ln 200A) |
2S<Tp 10S(ln 200A) |
12ln 20% |
4min(200A<ln 400A) |
4S<Tp10S(200A<ln 200A) |
|
Main Technical Specification
Type |
Rated
current ln(A) |
Pole number |
Rated insulation voltage(V) |
Rated working voltage Ue(V) |
Arcingover distance(mm) |
Rated limit short
circuit breaking capability(KA) |
Rated working short circuit breaking capability(KA) |
Operating performance(times) |
Overall dimension(mm) |
AC380V(400) |
AC660V(690) |
DC250 |
AC380V(400) |
AC660V(690) |
load |
unload |
L |
W |
H |
HS2-160s |
16,20,32,40,50,
63,80,100,125,160 |
3/4 |
690V
|
380V
660V
|
|
35 |
8 |
20 |
25 |
10 |
4000 |
6000 |
120 |
90/120 |
70 |
HS2-160H |
50 |
10 |
40 |
35 |
15 |
HS2-250S |
100,125,160,
180,200,225,250 |
35 |
10 |
40 |
35 |
15 |
2000 |
6000 |
170 |
105/140 |
103.5 |
HS2-250M |
50 |
16 |
40 |
40 |
20 |
HS2-250H |
65 |
18 |
40 |
50 |
25 |
HS2-400S |
200,225,250,
315,350,400 |
35 |
16 |
40 |
50 |
25 |
1000 |
4000 |
254 |
140/184 |
103.5 |
HS2-400M |
50 |
20 |
40 |
55 |
30 |
HS2-400H |
65 |
25 |
40 |
65 |
35 |
HS2-630S |
400,500,630 |
50 |
20 |
40 |
65 |
35 |
1000 |
4000 |
268 |
210/280 |
103.5 |
HS2-630M |
65 |
25 |
40 |
75 |
45 |
HS2-630H |
80 |
30 |
40 |
75 |
45 |
HS2-800S |
500,630,700,800 |
50 |
20 |
40 |
80 |
50 |
1000 |
4000 |
268 |
210/280 |
103.5 |
HS2-800M |
65 |
25 |
40 |
85 |
60 |
HS2-800H |
80 |
30 |
40 |
85 |
60 |
HS2-1250H |
800,1000,1250 |
3 |
80 |
30 |
|
85 |
60 |
500 |
2500 |
406 |
210 |
138.5 |
HS2-1600H |
1000,1250,1600 |
Notice : The technical data of normal one is the same as the intelligent one .
Intelligent STR Main Technical Indexs
Function L-step adjustment for protection against overload.Adjustment of the operating current l1=0.4+1xln with discreet coeffients as the value can be 0.4;0.5;0.6;0.7;0.8;0.9; and 1.
Time delay adjustment t1 of the protection against overload-step adjustment for values A-3s;b-6s;c-12s;d-18s when current is l=6l1.The diagram of the current curves is presented on fig.1
Adjustment of the transitory protection current against short circuit l3=X ¡Á l1 where X can take discreet value off;1.5;2;4;6;8;10.
|
Dimensions
Specification |
W |
W1 |
W2 |
W3 |
W4
3P/4P |
L |
L1 |
L2 |
L3 |
L4 |
L5 |
L6 |
H |
H1 |
H2 |
H3 |
H4 |
B |
B1 |
B2 |
B3 |
A |
A1 |
A2 |
d |
d1 |
D |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
HS2-160S.H |
120 |
90 |
30 |
45 |
90/120 |
125 |
120 |
74.5 |
72 |
45 |
63 |
102 |
93 |
75 |
70 |
42 |
75 |
30 |
30 |
45 |
15 |
102 |
100 |
63 |
18 |
4.5 |
M8 |
HS2-250 |
140 |
105 |
35 |
52.5 |
105/140 |
175 |
170 |
89.75 |
87.75 |
105 |
73.75 |
143 |
135 |
103.5 |
101.5 |
55 |
100 |
35 |
35 |
52.5 |
17.5 |
143 |
139 |
73.75 |
24 |
5.5 |
M12 |
HS2-400 |
183.75 |
140 |
43.75 |
70 |
105 |
259 |
254 |
127.75 |
125.75 |
105 |
107.25 |
218 |
135 |
103.5 |
101.5 |
62 |
108 |
43.75 |
43.75 |
65.5 |
22 |
218 |
214 |
107.25 |
24 |
5.5 |
M16 |
HS2-630
HS2-800 |
280 |
210 |
70 |
105 |
140 |
273 |
268 |
127.75 |
125.75 |
105 |
111.75 |
241 |
167.5 |
103.5 |
101.5 |
68 |
68 |
70 |
70 |
105 |
35 |
241 |
237 |
111.75 |
50 |
5.5 |
M24 |
Plug-in and front panel connection for overall and mounting dimension see Fig.7 and Table 8
Dimensions
specification |
W |
W1 |
W2 |
W3 |
W4 |
L |
L1 |
L2 |
L3 |
L4 |
H |
H1 |
H2 |
H3 |
H4 |
A
(3P/4P) |
B |
C |
d1 |
d2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
HS2-160S.H |
120 |
90 |
30 |
45 |
14 |
164 |
192 |
208 |
71 |
45 |
123 |
75 |
93 |
52 |
25 |
60/90 |
35 |
5.5 |
M8 |
4.5 |
HS2-250S.M.H |
140 |
105 |
35 |
52.5 |
20 |
175 |
210 |
230 |
85.25 |
105 |
153 |
103.5 |
135 |
52 |
31 |
70/105 |
100 |
47.75 |
¦Õ8 |
5 |
HS2-400S.M.H |
/ |
140 |
43.75 |
70 |
25 |
259 |
305 |
333 |
131.25 |
105 |
153 |
103.5 |
135 |
52 |
31 |
115 |
135 |
67.25 |
¦Õ10.5 |
5.5 |
Connection for overall and mounting dimension see Fig.8 and Table 9
Dimensions
specification |
W |
W1 |
W2 |
W3 |
W4 |
L |
L1 |
L2 |
L3 |
, L4 |
L5 |
H |
H1 |
H2 |
H3 |
H4 |
A |
B |
B1 |
B2 |
B3 |
d1 |
d2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
HS2-160S.H |
120 |
90 |
30 |
45 |
90/120 |
125 |
164 |
71 |
102 |
63 |
45 |
123 |
145 |
52 |
40 |
76 |
60/90 |
102 |
35 |
5.5 |
63 |
4.5 |
M8 |
HS2-250S.M.H |
140 |
105 |
35 |
52.5 |
105/140 |
175 |
175 |
85.25 |
143 |
73.75 |
105 |
153 |
184.5 |
50 |
48 |
100 |
70/105 |
143 |
100 |
47.75 |
43.75 |
5 |
M12 |
HS2-400S.M.H |
/ |
140 |
43.75 |
70 |
105 |
259 |
259 |
131.25 |
218 |
107.25 |
105 |
153 |
184.5 |
50 |
58 |
108 |
87.5 |
218 |
135 |
67.25 |
107.25 |
6 |
M16 |
|
|
|
|
|