Application
The contactor is suitable for using in the circuit up to the rated voltage 660V AC 50Hz or 60Hz, rated current 630A, for making and breaking, and for frequent starting and controlling the motor.After combined with the mechanical interlocking device, it becomes 3TD Series convertible contactor for Controlling, starting, breaking and Reversing of the motor. The products comply with IEC947 & VDE0660.
SpecificationsSpecifications
Type |
Rated
thermal
current
(A) |
Rated
operating
current at
380V(A) |
Rated
operating
current at
660V(A) |
The power of
controlled motor
(KW) |
Type of
auxiliary
contact |
380(V) |
660(V) |
1NO
1NC
1NO+1NC
2NO+2NC |
3TB40 |
22 |
9 |
7.2 |
4 |
5.5 |
3TB41 |
22 |
12 |
9.5 |
5.5 |
7.5 |
3TB42 |
35 |
16 |
13.5 |
7.5 |
11 |
3TB43 |
35 |
22 |
13.5 |
11 |
11 |
3TB44 |
55 |
32 |
18 |
15 |
15 |
2NO+2NC |
3TH Series AC Contactor
Application
The auxiliary contactors is the auxiliary suited by controlled circuit with voltage is AC 50/60Hz,660V and DC 660V.They control all kinds of magnetic coil and amplify or transfer signal to relative controlled element simultaneously.They are characterized by high performance & long service life.
Specifications
Rated
Voltage |
Rated operational current(A) |
Controllable motor power AC3(KW) |
le=AC11¡¢AC14 |
DC11 |
110V |
- |
0.9 |
- |
220V |
10 |
0.45 |
2.2 |
380V |
6 |
- |
4 |
440V |
- |
0.25 |
4 |
660V |
2 |
- |
4 |
Type |
Type of contact |
NO |
NC |
3TH30 |
4 |
1 |
31-OA |
3 |
2 |
22-OA |
2 |
3 |
13-OA |
1 |
4 |
04-OA |
- |
- |
3TH40/3TH80 40-OA |
4 |
1 |
31-OA |
3 |
2 |
22-OA |
2 |
3 |
13-OA |
1 |
4 |
04-OA |
- |
- |
3TH42/3TH8280-OA |
8 |
1 |
71-OA |
7 |
2 |
62-OA |
5 |
3 |
53-OA |
5 |
4 |
44-OA |
4 |
- |
3TF Ac Contactor
Application
3TF series AC contactor are suitable in electrical system with AC 50/60Hz, rated operational voltage up to 660V. In AC-3 usage, rated operational voltage up to 380V, rated operational current up to 630A to make or break remote motors or system. They form electromagnetic starters with suitable thermal overload or phase-failure. They are made according to IEC947, BS5424 & VDE0660.
The contactor is a straight motion mechanism having double-breaking contacts. The auxiliary contacts are arranged 2NO.2NC at most, It is employed the flexible locking connection between the contact support and core, three are no arcisolated panle in the Ie¡Ü22A contactors. in the le¡Ý32A contacotors. there are moulded arc-chute with arc-isolated panel. because all contacts are made of high nonfusibility and against corrosion silver alloy. All series products can be mounted by screws, le¡Ü32A contactor also by installation rail.
Technical Specification:
Type |
Rated
Thermal
current
(A) |
Rated
operation
current (A) |
Controllabe power of motor(KW) |
Type
of Auxiliary
contact |
AC-3 |
AC-4 |
380V |
660V |
380V |
660V |
380V |
660V |
3TF30 |
20 |
9 |
7 |
4 |
5.5 |
1.4 |
2.4 |
NO
NC
1NO+1NC
2NO+2NC |
3TF31 |
20 |
12 |
8.5 |
5.5 |
7.5 |
1.9 |
3.3 |
3TF32 |
30 |
16 |
12.5 |
7.5 |
11 |
3.5 |
6 |
3TF33 |
30 |
22 |
16.5 |
10 |
15 |
4 |
6.6 |
3TF34 |
55 |
32 |
24 |
15 |
22 |
7.5 |
13 |
3TF35 |
55 |
38 |
30 |
18.5 |
22 |
9 |
15.5 |
3TF40 |
20 |
9 |
7 |
4 |
5.5 |
1.4 |
2.4 |
3TF41 |
20 |
12 |
8.5 |
5.5 |
7.5 |
1.9 |
3.3 |
3TF42 |
30 |
16 |
12.5 |
7.5 |
11 |
3.5 |
6 |
3TF43 |
30 |
22 |
16.5 |
10 |
15 |
4 |
6.6 |
3TF44 |
55 |
32 |
24 |
15 |
22 |
7.5 |
13 |
3TF45 |
55 |
38 |
30 |
18.5 |
22 |
9 |
15.5 |
3TF46 |
80 |
45 |
40 |
22 |
37 |
12 |
20.8 |
2NC+2NO
4NC+4NO |
3TF47 |
80 |
63 |
60 |
30 |
55 |
14 |
24.3 |
3TF48 |
100 |
75 |
60 |
37 |
55 |
17 |
29.5 |
3TF49 |
100 |
85 |
80 |
45 |
75 |
21 |
36 |
3TF50 |
160 |
110 |
95 |
55 |
90 |
27 |
46.9 |
3TF51 |
160 |
140 |
120 |
75 |
115 |
35 |
60 |
3TF52 |
200 |
170 |
160 |
90 |
150 |
38 |
66 |
3TF53 |
210 |
205 |
165 |
110 |
160 |
50 |
86 |
3TF54 |
300 |
250 |
230 |
132 |
220 |
58 |
100 |
3TF55 |
300 |
300 |
260 |
160 |
250 |
66 |
114 |
3TF56 |
400 |
400 |
380 |
200 |
355 |
81 |
140 |
3TF68 |
630 |
600 |
600 |
335 |
560 |
160 |
278 |