Product Lists |
|
|
|
Product Search |
|
Product show |
|
HW30 Rotary Switch |
PDF Download |
|
|
Introduction
HW30 rotary switches series have six models,current rating up to 100A,suitable for wide variety of applications
HW30 rotary swtiches series widely control:50Hz AC,under 400V and 100A aircondition,water pump and electromotor and so on.
HW30 rotary switches series have six current ratings:20A,32A,40A,63A,80A and 100A,HW30 series has the fingerproof terminals,which offered extra advantage,HW30 rotary switches series excllence:insulated distance is larger than others,disconnecting quickly apply for DC switch,HW30 rotary switches series comply with:IEC 60947-3
Working conditions
1) Ambient temperature do not exceed 40≧,and the average temperature ,measured over a period of 24 hours,do not exceed 35≧
2) Ambient temperature do not less than -5≧
3) Should not be installed above 2000m above sea level
4) A clean environment was requied.
Current type:50HZ AC
Number of main contact:on or off
Mechanism life:10000 times/AC-23,6000 times/AC-3
Frequency:1 times/2 minutes
Classification
1.Classificed by utilization
1) AC-23A
2) AC-3
2.Classified by defending level
1) Without by defending box:IP2L0
2) With plastic box:IP65
Designation
Accessorical code:
Number poles:1P,2P,3P,4P,5P
Adding contacts:0 not order it ,1 order it
Eerthing termainal:0 not order it ,1 order it
Neutral terminal:0 not order it ,1 order it
Way of installation:1 pad-lock escutcheon plate
2 escutcheon plate
3 Doorlock safety switch
4 Doorlock safety switch with padlock system
Type of box:0 Not order it ,1 order IP65 plastic box
|
Type |
HW30-20 |
HW30-32 |
HW30-40 |
HW30-63 |
HW30-80 |
HW30-100 |
Rated insulation voltage Ui |
V |
HW30-20 |
HW30-32 |
HW30-40 |
HW30-63 |
HW30-80 |
HW30-100 |
Rated thermal current lth |
A |
HW30-20 |
HW30-32 |
HW30-40 |
HW30-63 |
HW30-80 |
HW30-100 |
Rated working current le
AC-23
AC-3 |
A
A |
15
11 |
22
15 |
30
22 |
43
36 |
57
43 |
70
57 |
Rated working voltage Ue |
V |
240 440 |
240 440 |
240 440 |
240 440 |
240 440 |
240 440 |
Power P
AC-23
AC-3 |
|
4 7.5
3 7.5 |
5.5 11
4 7.5 |
7.5 15
7.5 11 |
11 22
11 18.5 |
18.5 30
15 22 |
22 37
18.5 40 |
kW
kW |
Rated short current lcw/s |
A |
180 |
264 |
360 |
516 |
684 |
840 |
Rated limit current |
kA |
RL6-25/20
10 |
RL6-63/65
10 |
RL6-63/50
25 |
RL6-63/63
25 |
RL6-100/80
25 |
RL6-100/100
25 |
Type of fuse |
Rated short current |
Auxiliary contact
Accessories for choosing
Dimensions and installation
Square escutcheon plate
Type |
Escutcheon plate |
Dimensions(mm) |
Installation(mm)
|
HW30-20/3 |
|
HW30-32/3 |
|
HW30-40/3 |
|
HW30-63/3 |
|
HW30-80/3 |
|
HW30-100/3 |
HW30-20/6 |
HW30-32/6 |
HW30-40/6 |
HW30-63/6 |
HW30-80/6 |
HW30-100/6 |
|
M1 |
M2 |
M1 |
M2 |
M1 |
M2 |
M1 |
M2 |
M2 |
M3 |
M3 |
M2 |
M2 |
M2 |
M2 |
M3 |
M3 |
|
42 |
48 |
-- |
13.5 |
54 |
61 |
42 |
64 |
-- |
13.5 |
54 |
61 |
42 |
48 |
-- |
13.5 |
54 |
61 |
42 |
64 |
-- |
13.5 |
54 |
67 |
50 |
48 |
-- |
16 |
64 |
67 |
50 |
64 |
-- |
16 |
64 |
67 |
50 |
48 |
-- |
16 |
64 |
67 |
50 |
64 |
-- |
16 |
64 |
67 |
70 |
64 |
-- |
22.5 |
80 |
82 |
70 |
88 |
-- |
22.5 |
80 |
82 |
70 |
88 |
-- |
22.5 |
80 |
82 |
-- |
64 |
84 |
13.5 |
54 |
61 |
-- |
64 |
84 |
13.5 |
54 |
61 |
-- |
64 |
100 |
16 |
64 |
67 |
-- |
64 |
100 |
16 |
64 |
67 |
-- |
88 |
140 |
22.5 |
80 |
82 |
-- |
88 |
140 |
22.5 |
80 |
82 |
|
36 |
9 |
4.2 |
48 |
20 |
4.2 |
36 |
9 |
4.2 |
48 |
20 |
4.2 |
36 |
9 |
4.2 |
48 |
20 |
4.2 |
36 |
9 |
4.2 |
48 |
20 |
4.2 |
48 |
20 |
4.2 |
68 |
20 |
5.2 |
68 |
20 |
5.2 |
48 |
20 |
4.2 |
48 |
20 |
4.2 |
48 |
20 |
4.2 |
48 |
20 |
4.2 |
68 |
20 |
5.2 |
68 |
20 |
5.2 |
|
|
|
|
|